Ucell™ Cell Culture Flask, T-225, Vent Cap, Ultra Low Retention, TC-treated

$299.00

SKU: L3022A
Enter the quantity you would like, or drag the panel to find the quantity and price that best for you
Add to QuoteAuthorize OEM & ODM

Product details

The bottom of the ultra-low adsorption cell culture plate/dish/bottle is attached to the hydrogel with the surface covalent bond, which can minimize the cell attachment, cell activation, protein absorption and enzyme activation; The hydrogel had no cytotoxic effect. It can be used for cell non-adherent culture, organoids, spheroids and other cultures, for the collection and storage of rare samples, and has anti-adherent properties for strongly adhesive cells.

  • Surfaces minimize protein absorption, enzyme activation, and cell activation
  • The surface is non-cytotoxic, bioinert and non-degradable
  • Uniform floor space for easy stacking
  • Irreversible cover with condensing ring for reduced contamination
  • The top of the lid has a stacking ring for easy stacking
  • Irradiation sterilization, SAL10-6
  • No DNase/RNase, no pyrogen, no cytotoxicity

Product characteristics

Cap Vent Cap
Cell type No Treated:for suspension cells

TC Treated:for adherent cells

Growth area 225 cm²
Volume of work 900 ml
Vessel type Flask

 

Specifications

●Material
Product materialPolystyrene (PS)
●Purity & certification
Product category No medical device | IVD
Surface Treatment TC-treated
Sterilisation Gamma irradiation
Pyrogen-free Yes
Non-cytotoxicYes
BatchedYes
● Packaging
Qty/Pk1/ Pk
Qty/Cs5/ Cs
Please login to post questions

Question:

What does the TC-treated in the product name mean?

Wenjng
05-Nov-2024

Answer:

TC-treated means Tissue Cultured to treat the surface, improving the hydrophilicity of the polystyrene (PS) surface by means of corona discharge or gas plasma, improving the adhesion of the proteins required for cell adhesion to help cells adhere to the wall.

Question:

I want to be coated with extracellular matrix. Which surface culture consumables should I use?

Wenjng
05-Nov-2024

Answer:

You can choose a culture vessel with an untreated surface to self-coat the extracellular matrix. Of course, in this case, TC treatment surface utensils can also be used.

Question:

How do I use cell culture bottles with closed caps? What is the difference between the use of a lid with a filter membrane?

Wenjng
05-Nov-2024

Answer:

A cell culture bottle with a sealed lid provides a closed cell culture environment. If you need to connect to the air in the incubator, you need to loosen the cap slightly after the culture bottle is placed in the incubator to allow air to enter. Also, when taking out, you need to tighten the cap before taking out. The cap with filter membrane itself has a breathable function, and the filter membrane can prevent microbial contamination, so the cap can be tightened directly into the incubator when in use, but it should be noted that the filter membrane on the cap cannot be wet, and the wet filter membrane cannot ensure the passage of gas.

Question:

What do I hear a lot about T25, T175?

Wenjng
05-Nov-2024

Answer:

Taking T25 as an example, it refers to a cell culture bottle with a growth surface area of 25 cm2, which corresponds to different product numbers according to the type of bottle cap and different culture surfaces.

Question:

I bought the product No. xxxxxx, what is its growth area? How much medium should I add to grow my cells?

Wenjng
05-Nov-2024

Answer:

We recommend a medium dosage of 0.2-0.3mL/cm2.

Question:

The cell culture bottle/dish I purchased is not vacuum-packed, the bag looks loose, is there a quality problem?

Wenjng
05-Nov-2024

Answer:

The cell culture consumables are not vacuum-packed and are only manually pumped for ease of transport, so there are differences. In addition, the temperature and air pressure in different regions will also have an impact on the tightness of the package. If there is no air leakage in the package and the lid is not removed from the product, it will not affect the sterile performance and product quality of the product, please use it with confidence. If the package is damaged and leaky or the lid is coming off the product, take a photo and file a complaint through your distributor, taking care to include a photo of the product's outer box. When you receive the goods, please carefully confirm whether the outer box is damaged or deformed.

Question:

I can't use a package of culture supplies in one experiment. How should I keep it?

Wenjng
05-Nov-2024

Answer:

We cannot guarantee the sterility of the products after opening, so it is recommended that you store them in a sterile environment, control the ambient temperature and humidity, and avoid light/ultraviolet irradiation.

Question:

Culture flask/dish/plate, cells do not stick to the wall, is it a product quality problem?

Wenjng
05-Nov-2024

Answer:

Here are many factors that cause cell non-adherence, such as medium composition and pH, culture environment, digestive manipulation, cell type, cell generation, and so on. If you have been using the same product number to culture the same cell line for a long time and the cells are normally attached to the wall before but are not attached to the wall now, it is recommended that you record the batch number of the product used in both cases in time, and repeat the parallel experiment, that is, use the same source of cells to culture on the two batches of consumables respectively (pay attention to the use of the same source of media). Culture in the same incubator to determine the main cause of cell non-adherence.

Question:

The color of the culture bottle/dish/plate I bought this time is more yellow than that of last time, is it because of product quality?

Wenjng
05-Nov-2024

Answer:

Different batches of plastic consumables may turn yellow after irradiation sterilization, which is a normal phenomenon.

Question:

I want to grow suspended cells, which surface should I use?

gufengming
04-Dec-2024

Answer:

Suspension cells do not have the need for cell adhesion, and generally use untreated surface culture consumables. Suspended cells can also be cultured on the TC treated surface, but depending on the state and type of cells, some cells may appear to adhere to the wall.

Back to Top
Product has been added to your cart

Dr. Michael J. Williams

Hello! Welcome to the Ucallm. Click the button below to send me an email.Let me know your requirements and I’ll provide you with a preferential quote.

Powered by WpChatPlugins